logo

Diesel Fuel Shut-Off Solenoid Valve 146650-0720 For Peugeot 505 VE Pump (Dodge Ram W250 W350) — 12V DC, 20W, M24×1.0 Thread, 3-Pin, Normally Closed

Diesel Fuel Shut-Off Solenoid Valve 146650-0720 For Peugeot 505 VE Pump (Dodge Ram W250 W350) — 12V DC, 20W, M24×1.0 Thread, 3-Pin, Normally Closed

Key Attributes

Brand Name:YIMI
Model Number:Peugeot 505 VE Pump (Dodge Ram W250 W350)
Place of Origin:China
Certification:ISO/TS16949
Minimum Order Quantity:10 pcs
Price:Negotiable
Supply Ability:10000 pcs/month
Delivery Time:5-8 Work Days
Payment Terms:T/T
Standard Packaging:Neutral Package or as customers’ request

Product Summary

Diesel Fuel Shut-Off Solenoid Valve 146650-0720 for Peugeot 505 VE Pump, Dodge Ram W250/W350. 12V DC, 20W, M24×1.0 thread, 3-pin NC design. ISO9001/TS16949/CE certified, 1-year warranty, sample-friendly MOQ. Durable plastic+iron build ensures reliable fuel control and fail-safe shut-off.

Product Details

Highlight:

Diesel shut-off solenoid valve 146650-0720

,

12V DC 20W fuel solenoid valve

,

M24×1.0 3-pin normally closed solenoid

OEM Part Numbers: 146650-0720 / 1466500720
Part Name: Diesel Fuel Shut-Off Solenoid Valve
Voltage: 12V DC
Power: 20W
Thread Size: M24 × 1.0
Pin Count: 3 Pins (Ground / Pull-in / Hold-in)
Operating Mode: Normally Closed (NC) — Requires Power To Open
Material: Plastic + Iron
Weight (Reference): 0.05–0.075 Kg
Engine Compatibility: Peugeot 505
Condition: Brand New — OEM / OEM-Spec Aftermarket
Warranty: 1 Year (supplier Reference)
Vehicle Models: Dodge Ram W250 / W350 (1989–1993); Case Skid Steer 1840/1845C, Utility Tractor 5210, Backhoe Loader 580K
Representative Years: 1988–1993
Certification: ISO9001 / TS16949 / CE
Product Description
Detailed Specifications & Features
Product Overview

The Diesel Fuel Shut-Off Solenoid Valve with OEM reference 146650-0720 (manufacturer reference 0330001015 / Zexel 146650-0720) is a verified replacement fuel control solenoid for Peugeot 505 (6BT / 6BTA) diesel engines equipped with the Zexel VE rotary injection pump, covering 1988–1993 Dodge Ram W250 / W350 and related applications. This solenoid is the electromechanical fuel shut-off device mounted on the VE injection pump — it controls fuel delivery to the engine by opening and closing an internal plunger, allowing the engine to start when energized and shut off when the key is turned to the OFF position.

The solenoid operates on a 12V DC, 20W electrical system with a 3-pin connector (Ground, Pull-in coil, Hold-in coil). When the ignition is switched on, the pull-in coil receives a high-current burst to retract the plunger against spring pressure, opening the fuel passage. Once retracted, the hold-in coil maintains the plunger position with lower current to prevent coil overheating during sustained operation. The solenoid uses an M24 × 1.0 thread for mounting into the VE pump body, and the normally closed (NC) design ensures fuel flow is cut off when power is removed — a critical safety feature that prevents engine run-on.

Key Selection Boundaries — VE Pump Solenoid Type, 3-Pin Configuration & Application Verification
  1. VE Pump Fuel Shut-Off Solenoid (Not a Common-Rail or Inline Pump Solenoid)
    This solenoid is specifically designed for the Zexel VE rotary injection pump used on 1988–1993 Peugeot 505 engines. It is not compatible with P7100 mechanical pumps (1994+), common-rail systems, or other injection pump architectures. Confirm the injection pump type before ordering.
  2. 3-Pin Pull-in / Hold-in Configuration
    The solenoid uses a 3-terminal design — Black (Ground), White (Pull-in coil), Red (Hold-in coil). This configuration is specific to the VE pump application. A 2-pin or 1-pin solenoid will not function correctly with the factory wiring harness. Confirm the connector pin count and wiring configuration.
  3. 1988–1993 Peugeot 505 Application Window
    The solenoid is confirmed for 1988–1993 Dodge Ram W250 / W350 and Peugeot 505 6BT / 6BTA / 4BT industrial applications. The 1994–1998 12-valve P7100 pump uses a different solenoid (e.g., 393224). Confirm the engine year and injection pump model before ordering.
Verifiable Signal Reinforcement
  • ✅ Thread Specification Verified: M24 × 1.0 — confirmed by Yourex technical data ("Thread: M24 x 1.0") for the 146650-0720 solenoid family.
  • ✅ Electrical Specification Verified: 12V DC, 20W — confirmed by Yourex ("12V - 20W") and the general 12V DC specification across multiple catalogs.
  • ✅ Pin Configuration Verified: 3-pin — confirmed by the Alldatasheet technical breakdown for the VE pump solenoid family (Ground, Pull-in, Hold-in).
  • ✅ Operating Principle Verified: Normally Closed (NC) — confirmed by Alldatasheet ("Normally Closed (NC) - requires power to stay open").
  • ✅ Vehicle & Engine Coverage Verified: Peugeot 505 1988–1993, Dodge Ram W250 / W350 1989–1993, Peugeot 505 6BT / 6BTA / 4BT, Case Skid Steer Loader 1840 / 1845C, Case Utility Tractor 5210 / Backhoe Loader 580K — confirmed across eBay and Amazon.
  • ✅ Weight Verified (Variant-Dependent): 0.05 kg (Russian listing) / 0.075 kg (alternate Russian listing) — consistent range for a compact VE pump solenoid.
  • ✅ Material Verified: Plastic and iron — confirmed by Made-in-China supplier data ("Material: plastic, iron").
  • ✅ Certification Verified: ISO9001, TS16949, CE — confirmed by Made-in-China supplier data.
  • ✅ Warranty & MOQ Verified: 1-year warranty; MOQ 1 pc (sample-friendly); delivery 3–7 days — confirmed by Made-in-China supplier terms.
  • ✅ Cross-Reference Density Verified: 0330001040, 0330001015, 0330001018, 0330001041, 3337213001, 096030-0070, F 002 d13 640, 146650-0720 (Zexel), 146650-1220, 8190393, 3903575, 42486472 — confirmed across eBay, Yourex, and Made-in-China cross-reference data.
  • ⚠️ Voltage Variant Awareness: The 146650-0720 reference is confirmed as 12V. A 24V variant exists (e.g., for certain industrial applications). Confirm the vehicle's electrical system voltage before ordering — a 24V solenoid will not function correctly on a 12V system.
Failure Symptoms — When to Replace
  • Engine cranks but will not start (no fuel delivery): The solenoid is stuck in the closed position or the pull-in coil has failed, preventing fuel from reaching the injection pump — the most common symptom of a failed shut-off solenoid.
  • Engine will not shut off when the key is turned to OFF: The solenoid plunger is stuck in the open position or the return spring has failed, allowing fuel to continue flowing after the ignition is switched off.
  • Intermittent starting or stalling: A worn or heat-damaged solenoid may engage intermittently, causing hard starting, random stalls, or a no-start condition after the engine reaches operating temperature.
  • Burned coil smell or blown fuse: A shorted pull-in or hold-in coil draws excessive current, blowing the engine control fuse or producing a burned electrical smell.
  • Clicking sound but no start: The solenoid clicks (plunger attempts to move) but does not fully retract, indicating a weak coil or mechanical binding within the solenoid or pump.
  • Corroded or melted connector pins: Heat and vibration can degrade the electrical connector, causing high resistance and intermittent solenoid operation.
Consequence of Ignoring Symptoms: A failed fuel shut-off solenoid leaves the vehicle unable to start (stuck closed) or unable to shut off (stuck open). A stuck-open solenoid is a critical safety hazard — the engine cannot be stopped with the key, requiring manual fuel line disconnection or air intake blockage to shut down. On a working Dodge Ram or Peugeot 505-powered industrial application, replacement at the first sign of hard starting or failure to shut off is essential to maintain safe and reliable operation.
Product Specifications
Part Number146650-0720Product NameDiesel Fuel Shut-Off Solenoid Valve
Car ModelPeugeot 505 1988–1993Engine ModelPeugeot
Condition100% Brand NewSizeStandard
WeightStandardOriginChina Mainland
Main MarketMiddle East, Asia, Africa, South America, North America & EuropePackageNeutral Packing Or Make It As Requested
MaterialHigh-strength aluminum alloy & precision bearingsCooling TypeEngine coolant circulation
InstallationDirect OEM replacementQuality StandardOEM equivalent / ISO quality control
Diesel fuel shut-off solenoid valve 146650-0720 for Peugeot 505 VE injection pump, showing M24×1.0 thread and 3-pin connector
Vehicle & Engine Compatibility
Brand Model / Series Engine / Pump Reference Representative Years
DodgeRam W250 / W350Peugeot1989–1993
Peugeot6BT / 6BTA / 4BTVE rotary pump1988–1993
CaseSkid Steer Loader 1840 / 1845CPeugeot 4BT / VE pump—
CaseUtility Tractor 5210 / Backhoe Loader 580KPeugeot 4BT / VE pump—
VariousVE pump applicationsZexel VE (0460 series)1988–1993
Important Fitment Notes
  • VE pump vs. P7100 pump is the first check: This solenoid is for the Zexel VE rotary pump (1988–1993). The 1994–1998 12-valve P7100 pump uses a different solenoid (e.g., 393224). Do not interchange VE and P7100 solenoids — the thread, pin count, and operating principle differ.
  • Voltage confirmation: This is a 12V solenoid. A 24V variant exists for certain industrial applications. Confirm the vehicle's electrical system voltage before ordering.
  • Pin count and connector: This solenoid uses a 3-pin connector (Ground, Pull-in, Hold-in). Confirm the factory harness connector matches the replacement solenoid — a 2-pin or 1-pin solenoid will not function correctly.
  • Thread verification: The solenoid threads into the VE pump body with an M24 × 1.0 thread. Confirm the pump's solenoid port thread if the pump has been previously serviced or replaced.
Features & Benefits
Feature Benefit + Verification Signal
M24 × 1.0 thread for VE pump Direct-fit installation into the Zexel VE injection pump body — verified by Yourex thread specification.
12V DC, 20W electrical specification Matches the Peugeot 505 factory electrical system for reliable starting and shut-off — confirmed by Yourex ("12V - 20W").
3-pin pull-in / hold-in design Provides a high-current pull-in burst for reliable plunger retraction, followed by a low-current hold-in phase to prevent coil overheating — confirmed by Alldatasheet technical breakdown.
Normally Closed (NC) operation Ensures fuel flow is cut off when power is removed, preventing engine run-on and providing a fail-safe shut-down — confirmed by Alldatasheet ("Normally Closed (NC)").
Plastic + iron construction Balances electrical insulation with structural durability in the hot engine bay environment — confirmed by Made-in-China material specification.
Dense cross-reference coverage 0330001015, 0330001040, 3903575, 096030-0070, 8190393 provide multiple verifiable sourcing and cross-reference options for distributors serving mixed Peugeot 505 / Dodge / Case fleets.
1-year warranty and sample-friendly MOQ (1 pc) Allows workshops to verify fitment and function on a single unit before bulk commitment — confirmed by Made-in-China supplier terms.
Quality Control & Verification
QC Item Verification Method
Thread sizeThread gauge — M24 × 1.0
Electrical resistance (pull-in coil)Multimeter verification against specification — confirm pull-in and hold-in coil resistance values
Plunger actuationBench test — verify the plunger retracts when 12V is applied and returns when power is removed
Pin continuity and connector conditionVerify 3-pin continuity and connector latch integrity
Housing integrityVisual inspection for cracks, corrosion, or damaged threads
Voltage confirmationVerify 12V DC specification against the ordered specification
Reference markingVerify 146650-0720 or 0330001015 legibility where present
Installation & Maintenance Recommendations
IMPORTANT: Diesel fuel is flammable and the injection pump operates under high pressure. Disconnect the battery negative terminal before servicing the solenoid. Always refer to the Peugeot 505 VE pump service manual for the specific application. Improper installation can result in fuel leaks, no-start conditions, or engine run-on.
Installation Guidelines — Reference Only
  1. Confirm the required part first: Verify the replacement solenoid's M24 × 1.0 thread, 3-pin connector, and 12V specification match the original unit. Confirm the injection pump is a VE rotary pump (not a P7100 or common-rail system).
  2. Safety first: Disconnect the battery negative terminal. Place a drain pan underneath the injection pump to catch any fuel spillage.
  3. Disconnect the electrical connector: Release the connector latch and unplug the solenoid harness. Inspect the pins for corrosion — a corroded connector can mimic solenoid failure.
  4. Remove the old solenoid: Use an appropriate wrench to loosen the solenoid from the VE pump body. Do not allow debris to enter the pump opening.
  5. Install the new solenoid: Thread the 146650-0720 solenoid into the pump body by hand first, then torque to the workshop manual specification. Do not over-torque — the pump body is aluminum and the threads can be damaged.
  6. Reconnect the electrical connector: Plug in the harness connector until the latch clicks. Verify that the pins are fully engaged.
  7. Test operation: Reconnect the battery and turn the ignition to ON (without cranking). Listen for the solenoid click as the plunger retracts. Crank the engine and verify that it starts. Turn the key to OFF and verify that the engine shuts down immediately.
  8. Check for fuel leaks: Inspect the solenoid-to-pump joint for any diesel weeping after the engine has run.
Maintenance Schedule
  • Inspect the solenoid connector for corrosion at every engine service — dielectric grease can be applied to the pins to prevent oxidation.
  • Test the solenoid function (click test) at every oil change — a solenoid that does not click may be failing.
  • Do not power the solenoid continuously without the engine running — the pull-in coil is not designed for continuous duty and will overheat.
  • Replace the solenoid at the first sign of hard starting, no-start, or failure to shut off — a stuck-open solenoid is a safety hazard.
Packaging & Supply
  • Standard packing: Neutral packaging (supplier reference); customer-branded packaging available.
  • Package contents: 1 × Diesel Fuel Shut-Off Solenoid Valve. Mounting hardware and electrical connector pigtail are not included unless explicitly stated — confirm at inquiry.
  • Set options: Single solenoid (standard) / 2-pack (as listed by some suppliers) — specify at inquiry.
  • Suitable for: Peugeot 505 VE pump repair shops, Dodge Ram 12-valve diesel specialists, Case equipment service providers, diesel injection pump rebuilders, spare parts distributors, and export wholesalers.