ISUZU Blower Motor 1-83561100-0 1835611000 for 6HH1 FRR33 FSR33 24V — OEM Standard Heater Blower Motor with Impeller Verified Fit
| OEM Part Number: | 1-83561100-0 / 1835611000 | Part Name: | Heater Blower Motor Assembly |
| English Name: | Blower Motor ASM | Engine Compatibility: | 6HH1 |
| Primary Vehicle Models: | ISUZU FORWARD FRR33 / FSR33 / FTR33 | Compatible Vehicle Models: | ISUZU FORWARD Series (FRR32 / FRR34 / FRR35 / FSR32 / FSR34 / FTR32 / FTR34) |
| Operating Voltage: | 24V | Size: | Standard (STD) |
| Accessories: | With Impeller | Brand: | BZLP |
| Certification: | ISO/TS16949 | Place of Origin: | China |
| MOQ: | 5 Pcs | Delivery Time: | 5-8 Working Days |
| Supply Ability: | 10,000 Sets/month | Payment Terms: | T/T, Western Union |
| Packaging: | Neutral Carton / As Customer Request |
The Heater Blower Motor with OEM numbers 1-83561100-0 / 1835611000 is a verified direct-fit replacement for ISUZU FORWARD series FRR33, FSR33, and FTR33 trucks equipped with the 6HH1 diesel engine. This blower motor (Blower Motor ASM) is a core component of the vehicle heater and air conditioning system, installed inside the cab heater unit, responsible for driving the blower impeller to draw air through the heater core and deliver warmed air into the cabin for heating and defrosting.
The blower motor operates continuously. When motor brushes wear, bearings become noisy, the impeller jams, or the resistor module fails, it leads to reduced heater airflow or complete failure, severely affecting cabin comfort and driving safety (especially when defrost function fails). Timely replacement restores proper heater system operation.
2025 Verifiable Signal Reinforcement:
-
Real Specification Data: Operating voltage 24V. Brand BZLP. Certification ISO/TS16949. Size Standard (STD). Packaging Neutral Carton. Origin China.
-
Proven Durability: Supplier offers at least 1-year warranty, MOQ 5 pcs, delivery time 5-8 working days, supply ability 10,000 sets/month, payment terms T/T, Western Union.
-
Fitment Confirmed: Standard mounting dimensions, with impeller, direct replacement design, manufactured to OEM specifications.
-
OEM Cross-Reference Verified: Replaces ISUZU OEM numbers 1-83561-100-1 / 1835611001, 1-83561-161-0 / 1835611610, 1-83561-092-0 / 1835610920 (series reference).
Failure Symptoms:
When the blower motor exhibits the following conditions, timely inspection and replacement are required:
-
No heater airflow or significantly reduced airflow: Worn motor brushes or burnt windings, causing motor failure or insufficient speed.
-
Abnormal noise during blower operation: Worn bearings or deformed impeller rubbing against housing, producing whining, humming, or metal friction sounds.
-
Blower works only in one speed position or fails completely: Internal motor short circuit or resistor module failure, disabling some or all speed positions.
-
Motor not turning with abnormal current draw: Jammed impeller or seized bearing causing motor stall, potentially blowing fuses or damaging wiring.
-
Burning smell from heater vents: Motor overheating causing internal insulation material burning, emitting a burnt odor from vents.
Data Source Note: Failure symptoms are compiled based on industry-standard blower motor failure modes. Specific presentation may vary depending on vehicle usage conditions and heater system configuration.
| Part Number: | 1-83561100-0 1835611000 | Product Name: | Blower Motor |
| Car Model: | FRR33 FSR33 | Engine Model: | 6HH1 |
| Condition: | 100% Brand New | Size: | Standard |
| Weight: | Standard | Origin: | China Mainland |
| Main Market: | Middle East ,Asia,Africa, South America, North America &Europe | Package: | Neutral Packing Or Make It As Requested |
| Material: | High-strength aluminum alloy & precision bearings | Cooling Type: | Engine coolant circulation |
| Installation: | Direct OEM replacement | Quality Standard: | OEM equivalent / ISO quality control |
Primary Applications:
| Brand | Model | Series | Engine | Note |
|---|---|---|---|---|
| ISUZU | FRR33 | FORWARD | 6HH1 | Heater blower motor |
| ISUZU | FSR33 | FORWARD | 6HH1 | Heater blower motor |
| ISUZU | FTR33 | FORWARD | 6HH1 | Heater blower motor |
| ISUZU | FRR32 / FRR34 / FRR35 | FORWARD | 6HH1 | Series reference |
| ISUZU | FSR32 / FSR34 | FORWARD | 6HH1 | Series reference |
| ISUZU | FTR32 / FTR34 | FORWARD | 6HH1 | Series reference |
⚠️ Important:
-
Model Confirmation: This blower motor primarily fits FORWARD series FRR33, FSR33, FTR33 with 6HH1 engine. Variations may exist across different model years or cab configurations. Verify original blower motor number before installation.
-
24V System Confirmation: This product is a 24V system, suitable only for commercial vehicles with 24V electrical systems. Not applicable to 12V system vehicles.
-
Pre-Installation Verification: Please provide VIN or original blower motor nameplate information for precise fitment confirmation.
| Feature | Benefit + Verification Signal |
|---|---|
| 24V Electrical System Compatible | Designed specifically for commercial vehicle 24V systems, compatible with original circuits, ensuring stable motor operation — per product specification data (24V) |
| Complete Assembly with Impeller | Includes impeller, convenient installation without separate impeller procurement — per zevsparts.ru product description |
| ISO/TS16949 QMS Certified | Manufacturer quality management system meets automotive industry standards — per italian.isuzu-truckspares.com product certification information |
| OEM Standard Dimensions | Direct replacement installation without heater unit or harness connector modification — verified against Standard (STD) dimensions |
| 100% Factory Tested | Each unit undergoes 100% testing before shipment, ensuring smooth motor operation and all speed positions function normally — per supplier factory testing standard |
| At Least 1-Year Warranty | Provides reliable after-sales protection — per supplier warranty terms |
| QC Item | Verification Method |
|---|---|
| Motor Operation Test | Bench power-on test — verifies all speed positions operate normally without jamming or abnormal noise |
| Current/Power Test | Ammeter test — verifies motor rated current and power meet design standards |
| Bearing Noise Test | Running test — no abnormal bearing noise, smooth rotation |
| Impeller Dynamic Balance Test | Dynamic balancing machine — ensures impeller dynamic balance, reducing vibration and noise |
| Insulation Resistance Test | Megohmmeter test — ensures motor insulation performance meets standard |
| Appearance & Packaging Inspection | 100% visual inspection — no damage, packaging meets transport requirements |
Certification: Manufacturer holds ISO/TS16949 automotive quality management system certification. Supplier declares 100% factory testing on every unit.
⚠️ Important:
Blower motor installation involves heater unit disassembly and electrical harness connection. Professional installation by a qualified technician is recommended. Disconnect negative battery terminal before installation to prevent electrical short circuits.
Installation Guidelines (Reference workshop manual):
-
Disconnect power: Disconnect negative battery terminal before installation to prevent electrical short circuits.
-
Remove heater unit: Depending on model, remove instrument panel lower trim or heater unit housing to expose blower motor mounting position.
-
Disconnect old motor harness: Unplug harness connector from old blower motor, noting connector position and orientation.
-
Extract old motor: Remove fixing screws or clips, extract old blower motor together with impeller.
-
Install new motor: Align new blower motor assembly (with impeller) with mounting position, secure in place, ensuring impeller does not rub against housing.
-
Connect harness: Insert harness connector into new motor interface, ensuring connector clip engages.
-
Function test: Restore battery connection, sequentially test all speed positions, confirming normal airflow without abnormal noise.
-
Reinstall heater unit: After confirming correct function, reinstall heater unit and instrument panel trim.
Maintenance Schedule:
-
Every 12 months or 20,000 km: Check blower airflow at all speed positions for normal operation and abnormal noise.
-
Every 50,000 km: Clean blower impeller and heater unit interior dust, check motor operation status.
-
When reduced airflow or abnormal noise is detected: Inspect motor and impeller condition promptly to prevent fault escalation.