logo
Products
PRODUCTS DETAILS
Home > Products >
Precision-Molded Blades Cooling Fan with Heat-Resistant Composite for ISUZU NPR66 4HF1 Engine OEM Standard Fitment

Precision-Molded Blades Cooling Fan with Heat-Resistant Composite for ISUZU NPR66 4HF1 Engine OEM Standard Fitment

MOQ: 10 pcs
Price: Negotiable
Standard Packaging: Neutral Package or as customers’ request
Delivery Period: 5-8 Work Days
Payment Method: T/T,Western Union
Supply Capacity: 10000 pcs/month
Detail Information
Place of Origin
China
Brand Name
YIMI
Certification
ISO/TS16949
Model Number
ISUZU NPR66 Series
Part No:
8-97078662-0, 8970786620, 8-97094660-0, 8970946600
Engine Application:
ISUZU 4HF1 Diesel Engine (4.3L)
Blade Design:
Precision-Molded, Optimized Airflow
Material:
High-Grade, Heat-Resistant Composite
Mounting Type:
Bolt-On Fan Clutch Mount
Cooling Type:
Engine Coolant Circulation
Engine Displacement:
4.3L (4329cc)
Valvetrain:
OHV / SOHC
Highlight:

Precision-Molded Blades Cooling Fan

,

Heat-Resistant Composite Radiator Fan

,

OEM Standard Fitment Engine Cooling Fan

Product Description
Cooling Fan 8-97078662-0 For ISUZU NPR66 4HF1 Engine
Precision-engineered cooling fan draws air through the radiator, dissipating engine heat and maintaining optimal operating temperature for reliable performance in ISUZU NPR66 trucks with 4HF1 diesel engines.
Product Specifications
Part Number 8-97078662-0, 8970786620, 8-97094660-0, 8970946600
Product Name Cooling Fan / Radiator Fan / Engine Cooling Fan
Car Model ISUZU NPR66 Series
Engine Model ISUZU 4HF1 Diesel Engine (4.3L)
Condition 100% Brand New
Material High-strength aluminum alloy & precision bearings
Quality Standard OEM equivalent / ISO quality control
ISUZU Cooling Fan 8-97078662-0 for NPR66 4HF1 Engine
Features & Advantages
  • OE Quality: Manufactured to strict ISUZU dimensional and performance specifications for perfect fit and function
  • Optimized Blade Design: Precision-molded blades provide maximum airflow for efficient heat dissipation
  • Durable Construction: Heat-resistant composite material resists cracking, warping, and fatigue
  • Balanced Operation: Precision-balanced design minimizes vibration and reduces stress on cooling system components
  • Restores Cooling Performance: Eliminates overheating caused by damaged or inefficient fans
  • Protects the Engine: Maintains optimal operating temperature for engine reliability and longevity
  • Direct Replacement: Simple installation during cooling system service
  • Long Service Life: Engineered to withstand the rigors of heavy-duty commercial operation
Cooling Fan technical details and installation view
Vehicle & Engine Compatibility
This cooling fan is specifically designed for ISUZU medium-duty trucks with 4HF1 diesel engines.
  • ISUZU NPR66 – Medium-Duty Trucks
  • ISUZU NPR (various models with 4HF1 engine)
  • ISUZU NKR (select models with 4HF1 engine)
  • ISUZU ELF (select models with 4HF1 engine)
ISUZU 4HF1 Engine Specifications
  • 4-Cylinder, Inline Diesel
  • Displacement: 4.3L (4329cc)
  • Valvetrain: OHV / SOHC (depending on variant)
  • Widely used in NPR66 and various medium-duty trucks
Installation Notes
Professional installation recommended. Proper cooling system service is essential for optimal performance and safety.
  1. Disconnect battery – Disconnect the negative battery cable before beginning work
  2. Allow engine to cool – Ensure the engine is completely cool before beginning work
  3. Remove the fan shroud – Remove any shrouds or components blocking access to the fan
  4. Remove the drive belt – Loosen and remove the drive belt if necessary for access
  5. Remove the old fan – Unbolt the fan from the fan clutch or water pump hub
  6. Inspect the fan clutch – Check for wear, leaks, or damage; replace if necessary
  7. Inspect the radiator – Check for damage, debris, or blockage
  8. Clean the mounting area – Clean the fan clutch mounting surface and surrounding area
  9. Prepare the new fan – Inspect the new fan and verify it matches the original
  10. Install the new fan – Position the new fan on the fan clutch and secure with mounting bolts
  11. Torque to specification – Tighten bolts to manufacturer specification
  12. Reinstall the drive belt – Reinstall and adjust the drive belt tension if removed
  13. Reinstall the fan shroud – Reinstall the fan shroud or components removed for access
  14. Reconnect battery – Reconnect the negative battery cable
  15. Start the engine – Verify smooth, vibration-free fan operation
  16. Check for issues – Listen for unusual noise or vibration
  17. Verify cooling operation – Allow engine to reach operating temperature and verify proper cooling system function
Quality Control
  • Material Verification – Confirms composite material meets OE heat resistance and durability specifications
  • Dimensional Inspection – Blade diameter, mounting hole positions, and overall dimensions verified against OEM tolerances
  • Balancing Testing – Fan dynamically balanced to ensure smooth, vibration-free operation
  • Airflow Testing – Airflow performance verified to OE requirements
  • Impact Resistance Testing – Blade durability verified to resist stone and debris impact
  • Visual Inspection – 100% checked for defects, cracks, or warping
  • Packaged Safely – Protected and securely packaged to prevent damage during transit
Packaging and Delivery
  • Neutral export packing or customized packaging available
  • Carton or wooden case for safe transportation
  • Fast delivery for stock items
  • Shipping by Express Air or Sea
Inquiry
For pricing, availability, or bulk purchase of the Cooling Fan 8-97078662-0 For ISUZU NPR66 4HF1 Engine, please contact our sales team for a competitive quote and expert technical support.
Products
PRODUCTS DETAILS
Precision-Molded Blades Cooling Fan with Heat-Resistant Composite for ISUZU NPR66 4HF1 Engine OEM Standard Fitment
MOQ: 10 pcs
Price: Negotiable
Standard Packaging: Neutral Package or as customers’ request
Delivery Period: 5-8 Work Days
Payment Method: T/T,Western Union
Supply Capacity: 10000 pcs/month
Detail Information
Place of Origin
China
Brand Name
YIMI
Certification
ISO/TS16949
Model Number
ISUZU NPR66 Series
Part No:
8-97078662-0, 8970786620, 8-97094660-0, 8970946600
Engine Application:
ISUZU 4HF1 Diesel Engine (4.3L)
Blade Design:
Precision-Molded, Optimized Airflow
Material:
High-Grade, Heat-Resistant Composite
Mounting Type:
Bolt-On Fan Clutch Mount
Cooling Type:
Engine Coolant Circulation
Engine Displacement:
4.3L (4329cc)
Valvetrain:
OHV / SOHC
Minimum Order Quantity:
10 pcs
Price:
Negotiable
Packaging Details:
Neutral Package or as customers’ request
Delivery Time:
5-8 Work Days
Payment Terms:
T/T,Western Union
Supply Ability:
10000 pcs/month
Highlight

Precision-Molded Blades Cooling Fan

,

Heat-Resistant Composite Radiator Fan

,

OEM Standard Fitment Engine Cooling Fan

Product Description
Cooling Fan 8-97078662-0 For ISUZU NPR66 4HF1 Engine
Precision-engineered cooling fan draws air through the radiator, dissipating engine heat and maintaining optimal operating temperature for reliable performance in ISUZU NPR66 trucks with 4HF1 diesel engines.
Product Specifications
Part Number 8-97078662-0, 8970786620, 8-97094660-0, 8970946600
Product Name Cooling Fan / Radiator Fan / Engine Cooling Fan
Car Model ISUZU NPR66 Series
Engine Model ISUZU 4HF1 Diesel Engine (4.3L)
Condition 100% Brand New
Material High-strength aluminum alloy & precision bearings
Quality Standard OEM equivalent / ISO quality control
ISUZU Cooling Fan 8-97078662-0 for NPR66 4HF1 Engine
Features & Advantages
  • OE Quality: Manufactured to strict ISUZU dimensional and performance specifications for perfect fit and function
  • Optimized Blade Design: Precision-molded blades provide maximum airflow for efficient heat dissipation
  • Durable Construction: Heat-resistant composite material resists cracking, warping, and fatigue
  • Balanced Operation: Precision-balanced design minimizes vibration and reduces stress on cooling system components
  • Restores Cooling Performance: Eliminates overheating caused by damaged or inefficient fans
  • Protects the Engine: Maintains optimal operating temperature for engine reliability and longevity
  • Direct Replacement: Simple installation during cooling system service
  • Long Service Life: Engineered to withstand the rigors of heavy-duty commercial operation
Cooling Fan technical details and installation view
Vehicle & Engine Compatibility
This cooling fan is specifically designed for ISUZU medium-duty trucks with 4HF1 diesel engines.
  • ISUZU NPR66 – Medium-Duty Trucks
  • ISUZU NPR (various models with 4HF1 engine)
  • ISUZU NKR (select models with 4HF1 engine)
  • ISUZU ELF (select models with 4HF1 engine)
ISUZU 4HF1 Engine Specifications
  • 4-Cylinder, Inline Diesel
  • Displacement: 4.3L (4329cc)
  • Valvetrain: OHV / SOHC (depending on variant)
  • Widely used in NPR66 and various medium-duty trucks
Installation Notes
Professional installation recommended. Proper cooling system service is essential for optimal performance and safety.
  1. Disconnect battery – Disconnect the negative battery cable before beginning work
  2. Allow engine to cool – Ensure the engine is completely cool before beginning work
  3. Remove the fan shroud – Remove any shrouds or components blocking access to the fan
  4. Remove the drive belt – Loosen and remove the drive belt if necessary for access
  5. Remove the old fan – Unbolt the fan from the fan clutch or water pump hub
  6. Inspect the fan clutch – Check for wear, leaks, or damage; replace if necessary
  7. Inspect the radiator – Check for damage, debris, or blockage
  8. Clean the mounting area – Clean the fan clutch mounting surface and surrounding area
  9. Prepare the new fan – Inspect the new fan and verify it matches the original
  10. Install the new fan – Position the new fan on the fan clutch and secure with mounting bolts
  11. Torque to specification – Tighten bolts to manufacturer specification
  12. Reinstall the drive belt – Reinstall and adjust the drive belt tension if removed
  13. Reinstall the fan shroud – Reinstall the fan shroud or components removed for access
  14. Reconnect battery – Reconnect the negative battery cable
  15. Start the engine – Verify smooth, vibration-free fan operation
  16. Check for issues – Listen for unusual noise or vibration
  17. Verify cooling operation – Allow engine to reach operating temperature and verify proper cooling system function
Quality Control
  • Material Verification – Confirms composite material meets OE heat resistance and durability specifications
  • Dimensional Inspection – Blade diameter, mounting hole positions, and overall dimensions verified against OEM tolerances
  • Balancing Testing – Fan dynamically balanced to ensure smooth, vibration-free operation
  • Airflow Testing – Airflow performance verified to OE requirements
  • Impact Resistance Testing – Blade durability verified to resist stone and debris impact
  • Visual Inspection – 100% checked for defects, cracks, or warping
  • Packaged Safely – Protected and securely packaged to prevent damage during transit
Packaging and Delivery
  • Neutral export packing or customized packaging available
  • Carton or wooden case for safe transportation
  • Fast delivery for stock items
  • Shipping by Express Air or Sea
Inquiry
For pricing, availability, or bulk purchase of the Cooling Fan 8-97078662-0 For ISUZU NPR66 4HF1 Engine, please contact our sales team for a competitive quote and expert technical support.
Sitemap |  Privacy Policy | China Good Quality Isuzu Cars Parts Supplier. Copyright © 2024-2026 Yimi (Guangzhou) Automotive Parts Co, Ltd . All Rights Reserved.